Table 3 Results from receiver operating characteristic (ROC) analysis to distinguish MCI-AD from MCI-LB

From: Quantitative EEG as a biomarker in mild cognitive impairment with Lewy bodies

EEG measure

AUC [95% CI]

Cutoff for MCI-LB

Sensitivity

Specificity

Delta power

0.54 [0.41, 0.67]

> 21.9

0.23

0.89

Theta power

0.60 [0.47, 0.73]

> 10.7

0.33

0.89

Pre-alpha power

0.68 [0.56, 0.81]

> 28.1

0.56

0.83

Alpha power

0.66 [0.53, 0.78]

< 20.5

0.41

0.97

Beta power

0.71 [0.59, 0.83]

< 19.0

0.61

0.81

Theta/alpha ratio

0.64 [0.51, 0.77]

> 0.56

0.49

0.83

DF, all electrodes

0.70 [0.58, 0.82]

< 7.1

0.51

0.86

DF, occipital electrodes

0.69 [0.57, 0.81]

< 7.1

0.51

0.86