Instrument Number of articles* N healthy controls N
MCI
n Sensitivity Specificity n AUC n Internal consistency n Inter-rater reliability n Test-retest reliability (mean time between tests)
Phototest 2 85 98 183 77.1 91.5 91 93       
Qmci 3 851 305 1416 85.7 85.7 307 92.3      30 0.93 (31.1 days)
AQT 1 47 75 122 80 76 122 85      122 0.88 (16 weeks)
SIS 1 375 440 815 34.3 90.1 815 63.2       
6 CIT 1 130 67 197 66 70 197 71       
10-CS 1 106 56 162 60.5 94.3 162 85       
K-D test 1 135 39 174 92.3   174 71       